null
Endress+Hauser

Space-saving Coriolis Flowmeter Proline Promass I 300

(No reviews yet) Write a Review
SKU:
Proline Promass I 300 Series
MPN:
Proline Promass I 300
Weight:
0.00 Grams
+971 4 259 5133

Description

Application

The Promass I's straight single-tube design allows for precise in-line viscosity measurement along with mass flow, density, and temperature measurement. With its compact transmitter, the Promass I 300 provides high flexibility for operation and system integration, offering one-sided access, remote display options, and enhanced connectivity. Its built-in Heartbeat Technology ensures measurement reliability and supports compliance verification. The measuring principle is independent of physical properties like fluid viscosity or density. Ideal for measuring liquids and gases in applications that require low pressure drop and gentle fluid handling. Device Features:

  • Straight, easy-to-clean single-tube system
  • TMB technology
  • Titanium measuring tube
  • Compact dual-compartment housing with up to three I/Os
  • Backlit display with touch controls and WLAN access
  • Option for remote display

Benefits

  • Energy efficiency: Full bore design minimizes pressure loss.
  • Multifunctional measurement: Combines flow, density, and temperature measurements, reducing the need for multiple measuring points.
  • Compact installation: No inlet or outlet runs required, saving space.
  • Comprehensive process access: Numerous I/Os and Ethernet connections provide full access to process and diagnostic data.
  • Simplified configuration: Freely configurable I/O functionality reduces complexity.
  • Integrated verification: Heartbeat Technology ensures built-in measurement verification and reliability.

Documents

You may want to read this product's catalog. If so, please click to view the Proline Promass I 300 Series datasheet.

SPECIFICATIONS

Liquids Specifications

Measuring principle Coriolis
Product headline Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Max. measurement error Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design
Degree of protection IP66/67, type 4X enclosure
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Gas Specifications

Measuring principle Coriolis
Product headline Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6615 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design
Degree of protection Standard: IP66/67, Type 4X enclosure
Option: IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Viscosity Specification

Measuring principle Coriolis
Product Headline Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Density Specifications

Measuring principle Coriolis
Product headline Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: Titanium grade 9; Connection: Titanium grade 2
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Max. measurement error Mass flow (liquid): ±0.10 %, Volume flow (liquid): ±0.10 %, Mass flow (gas): ±0.50 %, Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180,000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design
Degree of protection IP66/67, type 4X enclosure, Option: IP69
Display/Operation 4-line backlit display with touch control (operation from outside), Configuration via local display and operating tools possible, Remote display available
Outputs 3 outputs: 4-20 mA HART (active/passive), 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Relay output
Inputs Status input, 4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-Tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Density/Concentration Specifications

Measuring principle Coriolis
Product headline Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: Titanium grade 9; Connection: Titanium grade 2
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Max. measurement error Mass flow (liquid): ±0.10 %, Volume flow (liquid): ±0.10 %, Mass flow (gas): ±0.50 %, Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180,000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design
Degree of protection IP66/67, type 4X enclosure, Option: IP69
Display/Operation 4-line backlit display with touch control (operation from outside), Configuration via local display and operating tools possible, Remote display available
Outputs 3 outputs: 4-20 mA HART (active/passive), 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Relay output
Inputs Status input, 4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-Tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP
View AllClose