Description
Application
The Promass I's straight single-tube design allows for precise in-line viscosity measurement along with mass flow, density, and temperature measurement. With its compact transmitter, the Promass I 300 provides high flexibility for operation and system integration, offering one-sided access, remote display options, and enhanced connectivity. Its built-in Heartbeat Technology ensures measurement reliability and supports compliance verification. The measuring principle is independent of physical properties like fluid viscosity or density. Ideal for measuring liquids and gases in applications that require low pressure drop and gentle fluid handling. Device Features:
- Straight, easy-to-clean single-tube system
- TMB technology
- Titanium measuring tube
- Compact dual-compartment housing with up to three I/Os
- Backlit display with touch controls and WLAN access
- Option for remote display
Benefits
- Energy efficiency: Full bore design minimizes pressure loss.
- Multifunctional measurement: Combines flow, density, and temperature measurements, reducing the need for multiple measuring points.
- Compact installation: No inlet or outlet runs required, saving space.
- Comprehensive process access: Numerous I/Os and Ethernet connections provide full access to process and diagnostic data.
- Simplified configuration: Freely configurable I/O functionality reduces complexity.
- Integrated verification: Heartbeat Technology ensures built-in measurement verification and reliability.
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass I 300 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials | Measuring tube: Titanium grade 9 Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design |
Degree of protection | IP66/67, type 4X enclosure IP69 |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Gas Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials | Measuring tube: Titanium grade 9 Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design |
Degree of protection | Standard: IP66/67, Type 4X enclosure Option: IP69 |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Viscosity Specification
Measuring principle | Coriolis |
Product Headline | Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
Density Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials | Measuring tube: Titanium grade 9; Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
Max. measurement error | Mass flow (liquid): ±0.10 %, Volume flow (liquid): ±0.10 %, Mass flow (gas): ±0.50 %, Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180,000 kg/h (0 to 6600 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design |
Degree of protection | IP66/67, type 4X enclosure, Option: IP69 |
Display/Operation | 4-line backlit display with touch control (operation from outside), Configuration via local display and operating tools possible, Remote display available |
Outputs | 3 outputs: 4-20 mA HART (active/passive), 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
Product safety | CE, C-Tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Density/Concentration Specifications
Measuring principle | Coriolis |
Product headline | Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials | Measuring tube: Titanium grade 9; Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity |
Max. measurement error | Mass flow (liquid): ±0.10 %, Volume flow (liquid): ±0.10 %, Mass flow (gas): ±0.50 %, Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180,000 kg/h (0 to 6600 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F) |
Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygienic transmitter design |
Degree of protection | IP66/67, type 4X enclosure, Option: IP69 |
Display/Operation | 4-line backlit display with touch control (operation from outside), Configuration via local display and operating tools possible, Remote display available |
Outputs | 3 outputs: 4-20 mA HART (active/passive), 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Relay output |
Inputs | Status input, 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
Product safety | CE, C-Tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |