Endress+Hauser
Space-saving Coriolis Flowmeter Proline Promass Q 500
- SKU:
- Proline Promass Q 500 Series
- MPN:
- Proline Promass Q 500
- Weight:
- 0.00 Grams
Description
Application
The Proline Promass Q 500 delivers exceptional accuracy for measuring mass flow, volume flow, and density. It is a top choice for custody transfer applications and is optimized for liquid applications where entrained gas is present. Featuring an advanced remote transmitter, the Promass Q 500 enhances installation flexibility and ensures operational safety in challenging environments. The integrated Heartbeat Technology ensures safe and reliable processes. The measurement principle operates independently of the physical properties of fluids, such as viscosity and density, providing consistent performance. The device ensures top-tier measurement performance for custody transfer, density measurements, and operation under demanding process conditions. Device properties:
- Mass/volume flow: ±0.05% measurement error (PremiumCal)
- Density: ±0.1 kg/m³ measurement error (optional)
- High turndown ratio with minimal pressure loss and zero-point stability
- Compact dual-compartment housing with up to 3 I/Os
- Backlit display with touch control and WLAN access
- Optional remote display available
Benefits
- Ensured measurement quality with unmatched accuracy for mass flow, volume flow, and density
- Optimized for liquids containing entrained gas using MFT (Multi-Frequency Technology)
- Reduces the need for multiple measuring points with multivariable measurement capabilities (flow, density, and temperature)
- Saves installation space due to the absence of in-/outlet run requirements
- Full access to process and diagnostic data with multiple configurable I/Os and Ethernet connectivity
- Simplified system design with configurable I/O functionality
- Built-in verification with Heartbeat Technology for continuous monitoring and diagnostics
Documents
You may want to read this product's catalog. If so, please click to view the Proline Promass Q 500 Series datasheet.SPECIFICATIONS
Liquids Specifications
Measuring principle | Coriolis |
Product Headline | Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow, and density. Highest measurement performance for custody transfer, density, and under tough process conditions. |
Sensor features | Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 25 to 250 (1 to 10") |
Wetted materials | Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications Connection: 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.25 % Density (liquid): ±0.2 kg/m³ (standard), ±0.1 kg/m³ (option) |
Measuring range | 0 to 2 400 000 kg/h (0 to 88183 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +205°C (–58 to +401 °F) Option: –196 to +150 °C (–321 to +302 °F) |
Ambient temperature range | Standard: - 4 to +60 °C (–4 to +140 °F) Option: –60 to +60 °C (–76 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69 Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids) OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids) NTEP (Liquids other than water, Cryogenic liquids) |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Gas Specifications
Measuring principle | Coriolis |
Product Headline | Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow, and density. Highest measurement performance for custody transfer, density, and under tough process conditions. |
Sensor features | Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 25 to 250 (1 to 10") |
Wetted materials | Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications Connection: 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.25 % Density (liquid): ±0.2 kg/m³ (standard), ±0.1 kg/m³ (option) |
Measuring range | 0 to 2 400 000 kg/h (0 to 88183 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +205°C (–58 to +401 °F) Option: –196 to +150 °C (–321 to +302 °F) |
Ambient temperature range | Standard: - 40 to +60 °C (–40 to +140 °F) Option: –60 to +60 °C (–76 to +140 °F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree of protection | IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids) OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids) NTEP (Liquids other than water, Cryogenic liquids) |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |
Steam Specifications
Measuring principle | Coriolis |
Product Headline | Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow, and density. Highest measurement performance for custody transfer, density, and under tough process conditions. |
Sensor features | Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
Density Specifications
Measuring principle | Coriolis |
Product Headline | Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow, and density. Highest measurement performance for custody transfer, density, and under tough process conditions. |
Sensor features | Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 25 to 250 (1 to 10") |
Wetted materials | Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications Connection: 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.25 % Density (liquid): ±0.2 kg/m³ (standard), ±0.1 kg/m³ (option) |
Measuring range | 0 to 2,400,000 kg/h (0 to 88,183 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +205°C (–58 to +401°F) Option: –196 to +150°C (–321 to +302°F) |
Ambient temperature range | Standard: -40 to +60°C (–40 to +140°F) Option: –50 to +60°C (–58 to +140°F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Other approvals and certificates | CE, C-tick, EAC marking Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids) OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids) NTEP (Liquids other than water, Cryogenic liquids) MC (Liquids other than water, Cryogenic liquids) LR approval, DNV approval, ABS approval, BV approval PED, CRN, AD 2000 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK 3-A, EHEDG, cGMP |
Density/Concentration Specifications
Measuring principle | Coriolis |
Product headline | Innovative specialist for challenging applications, as remote version with up to 4 I/Os. Secured measuring quality – unmatched accuracy of mass flow, volume flow, and density. Highest measurement performance for custody transfer, density, and under tough process conditions. |
Sensor features | Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology). Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measurement error ±0.05 % (PremiumCal). Density: measurement error ±0.2 kg/m³. High turndown due to low pressure loss/zero point. |
Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range | DN 25 to 250 (1 to 10") |
Wetted materials | Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications Connection: 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measurement error | Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.25 % Density (liquid): ±0.2 kg/m³ (standard), ±0.1 kg/m³ (option) |
Measuring range | 0 to 2,400,000 kg/h (0 to 88,183 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | Standard: –50 to +205°C (–58 to +401°F) Option: –196 to +150°C (–321 to +302°F) |
Ambient temperature range | Standard: –4 to +60°C (–4 to +140°F) Option: –60 to +60°C (–76 to +140°F) |
Sensor housing material | 1.4404 (316L), highest corrosion resistance Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L |
Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
Degree of protection | IP66/67, type 4X enclosure. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
Product safety | CE, C-tick, EAC marking |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids) OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids) NTEP (Liquids other than water, Cryogenic liquids) |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Hygienic approvals and certificates | 3-A, EHEDG, cGMP |