Description
Application
The T15 Explosion-proof RTD thermometer is designed for direct use within existing thermowells, featuring a range of transmitter housing options to accommodate specific application and space requirements. This device ensures high measurement accuracy and reliability, with a variety of connection types, dimensions, and materials such as 316L stainless steel and Hastelloy C276, allowing for versatile application possibilities.
Engineered for challenging environments, the T15 temperature sensor is an RTD assembly that is FM and CSA approved, making it suitable for use in explosive areas. The sensor comprises a measurement probe with an insulated RTD element and sheath.
This sensor assembly is ideal for use in process industries, including:
- Chemical
- Petrochemical
- Refineries
- Offshore Platforms
Benefits
- FM/CSA XP Class I, Div. 1 approved temperature assemblies ensure maximum safety.
- One-stop solution for temperature measurement needs, featuring a world-class transmitter with an integrated sensor for demanding process industry applications.
- Ready-to-use straight out of the box, simplifying installation and removal.
- Enhanced galvanic isolation on most devices (2 kV) for improved safety.
- Streamlined model structure offers competitive pricing and excellent value, with easy ordering and reordering. A single model number includes the sensor, thermowell, and transmitter assembly, providing a comprehensive point solution.
- All iTEMP transmitters deliver long-term stability with a deviation of ≤0.05% per year.
SPECIFICATIONS
Thermometer Specifications
Measuring principle
|
Resistance Temperature Detector
|
Characteristic / Application
|
Explosion Proof US style modular temperature assembly for heavy duty applications with extension to be used with existing thermowell
|
Thermowell / protection tube
|
to be used with thermowell
|
Insert / probe
|
mineral insulated (MI), flexible PTFE-insulated, rigid
|
Outer diameter protection tube / Insert
|
Not applicable
|
Max. immersion length on request
|
up to 100" (2540 mm) others on request
|
Material protection tube/ thermowell
|
Sensor sheath 316/316L
|
Optional coating
|
Not defined
|
Process connection
|
male thread: NPT1/2"
|
Tip shape
|
straight
|
Surface roughness Ra
|
Not defined
|
Operating temperature range
|
PT100 WW: -200 °C … 600 °C (-328 °F … 1.112 °F) PT100 TF: -50 °C … 200 °C (-58 °F … 392 °F)
|
Max. process pressure (static)
|
Not applicable
|
Accuracy
|
class A acc. to IEC 60751 class B acc. to IEC 60751
|
Response time
|
63% rt = 3 s
|
Integration head transmitter
|
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
|
Ex - approvals
|
FM XP DIP Class I,II,III Div. 1+2, Grp.A-G FM XP NI DIP Class I,II,III Div. 1+2, Grp.A-G CSA XP DIP Class I,II,III Div. 1+2, Grp.B-G CSA XP NI DIP Class I,II,III Div. 1+2, Grp.B-G FM/CSA XP DIP Class I,II,III Div. 1+2, FM Grp.A-G, CSA Grp.B-G FM/CSA XP NI DIP Class I,II,III Div.1+2 FM Grp.A-G, CSA Grp.B-G CSA C/US XP, DIP I, II, III/1/A-G cCSAus General Purpose
|
Certification |
SIL (transmitter only)
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser T15Series datasheet.