Endress+Hauser
T54 Explosion proof TC thermometer, US style
- SKU:
- T54 Explosion proof TC thermometer, US style series
- Weight:
- 0.00 Grams
Description
Application
The T54 Explosion Proof TC Thermometer is built for challenging and safety-critical environments, particularly in the Chemical, Oil & Gas, and Energy sectors. It is designed to withstand extreme conditions such as harsh environments, corrosive materials, and high pressures, thanks to the use of durable thermowells and specialized materials. The thermometer can be equipped with an optional head transmitter that supports all standard communication protocols, ensuring greater measurement accuracy and reliability compared to conventional wired sensors. Additionally, the device offers flexible configuration options.
This sensor assembly is ideal for use in various process industries, including:
- Chemicals
- Petrochemicals
- Refineries
- Offshore Platforms
Benefits
- FM/CSA XP Class I, Div. 1 certified temperature assemblies for optimal safety
- Comprehensive temperature measurement solutions from a single source, with world-class transmitters integrated with sensors for demanding industrial applications
- Ready to use straight out of the box for quick installation and removal
- Enhanced galvanic isolation on most devices (2 kV) for increased safety and performance
- Streamlined model structure: competitively priced, easy to order and reorder, with a single model number covering the sensor, thermowell, and transmitter for a complete solution
- iTEMP transmitters offer long-term stability, with a deviation of ≤0.05% per year
SPECIFICATIONS
Thermometer Specifications
Measuring principle
|
Thermocouple
|
Characteristic / Application
|
Explosion Proof US style modular temperature assembly for heavy duty applications flanged process connection with extension incl. Thermowell
|
Thermowell / protection tube
|
bar stock (drilled)
|
Insert / probe
|
mineral insulated (MI), flexible
|
Outer diameter protection tube / Insert
|
7/8'' (22,23 mm) 17/16'' (26,99 mm)
|
Max. immersion length on request
|
up to 22.5" (571 mm) others on request
|
Material protection tube/ thermowell
|
316/316L auf Anfrage
|
Optional coating
|
available on request
|
Process connection
|
flange: ASME 1" 150 RF (B16.5) ASME 1" 300 RF (B16.5) ASME 1" 600 RF (B16.5) ASME 1,5" 150 RF (B16.5) ASME 1,5" 300 RF (B16.5) ASME 1,5" 600 RF (B16.5) ASME 2" 150 RF (B16.5) ASME 2" 300 RF (B16.5) ASME 2" 600 RF (B16.5)
|
Tip shape
|
straight tapered
|
Surface roughness Ra
|
32 μin (0.80 μm)
|
Operating temperature range
|
Type T: -270 °C ...400 °C (-454 °F ...752 °F) Type J: -210 °C ...1200 °C (-346 °F ...2.192 °F) Type E: -270 °C ...1.000 °C (-454 °F ...1.832 °F) Type K: -270 °C ...1.372 °C (-454 °F ...2.500 °F) Type N: -270 °C ...1.300 °C (-454 °F ...2.372 °F)
|
Max. process pressure (static)
|
at 20°C : 500bar (7.252 psi) depends on configuration
|
Accuracy
|
Standard acc. to ASTM E-230 Special acc. to ASTM E-230
|
Response time
|
depending on configuration 63% rt = 15 s
|
Integration head transmitter
|
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
|
Ex - approvals
|
FM XP CSA XP FM/CSA XP CSA GP
|
Certification
|
SIL (transmitter only)
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser T54 Series datasheet.