Autonics
Modular Multi-Channel High Performance Temperature Controllers TMH Series
- SKU:
- TMH Series
- MPN:
- TMH
- Weight:
- 251.00 Grams
Description
Product Overview
The TMH Series modular multi-channel high-performance temperature controllers offer a versatile solution for precise temperature management across multiple channels. Designed for industrial applications requiring simultaneous control of 2 or 4 input/output channels, these controllers feature a high-speed sampling rate of 50 ms and an impressive measurement accuracy of ±0.3%. The TMH Series supports simultaneous heating and cooling control, making it ideal for complex temperature regulation tasks. One of the key benefits of the TMH Series is its modular design, which allows for easy expansion. Users can connect up to 32 units, managing as many as 128 channels without the need for additional wiring for power or communication. The system’s flexibility extends further with the ability to connect up to 16 communication modules to a master device, supporting a total of 1,024 control channels. Additionally, the TMH Series offers various option modules, including analog input/output modules, digital input/alarm output modules, and CT input modules. Communication modules are available for PLC ladder-less communication (RS422/485) and Ethernet. The system supports parameter configuration and status monitoring via PC connections using USB, RS422/RS485, or Ethernet.
Key Features
Multi-Channel Control
The TMH Series supports 2-channel and 4-channel configurations, with the capability to expand up to 32 units, managing 128 channels. This flexibility makes it suitable for large-scale applications requiring extensive temperature control.
High-Speed Sampling and Accuracy
With a sampling rate of 50 ms and measurement accuracy of ±0.3%, the TMH Series ensures precise and reliable temperature control, even in demanding environments.
Simultaneous Heating and Cooling Control
The TMH Series offers simultaneous heating and cooling control, enhancing its versatility in complex temperature management scenarios.
Modular Design for Easy Expansion
The modular design allows for seamless expansion of control channels and integration of additional option modules without requiring extra wiring for power or communication.
Comprehensive Option Modules
Various option modules are available to enhance the functionality of the TMH Series:
- Analog Input/Output Modules (TMHA Series): Supports 4 channels with various input types, temperature ranges, and transmission outputs.
- Digital Input/Alarm Output Modules (TMHE Series): Provides 8 digital inputs and 8 alarm outputs.
- CT Input Modules (TMHCT Series): Allows for monitoring current with 8 CT inputs.
Advanced Communication Capabilities
The TMH Series supports advanced communication options through dedicated modules:
- RS422/RS485 (TMHC-22LE): Supports Modbus RTU and PLC ladder-less communication.
- Ethernet (TMHC-22EE): Offers Modbus TCP for efficient network integration.
DAQMaster Software
For enhanced device management, the DAQMaster software allows users to configure parameters and monitor the system status via a PC. The software is compatible with USB, RS422/RS485, and Ethernet connections.
Control Module Specifications
- Channels: 2 or 4 channels.
- Sampling Period: 50 ms (synchronous sampling for 2 or 4 channels).
- Input Specifications: Supports Thermocouple, RTD, and Analog inputs.
- CT Input: Range of 0.0 - 50.0A with a CT ratio of 1/1,000 and a measurement accuracy of ±5% F.S. ±1 digit.
- Digital Input: ON: ≤ 1 kΩ, OFF: ≥ 100 kΩ, with a solid-state input having a residual voltage of ≤ 0.9 V and leakage current of ≤ 0.5 mA.
- Control Type: Supports heating, cooling, and combined heating & cooling with ON/OFF, P, PI, PD, and PID control types.
- Control Output: Available as Relay, SSR drive, or Current output with various specifications.
- Alarm Output: 250 VACᜠ 3 A 1a with a mechanical life cycle of ≥ 10,000,000 operations and electrical life cycle of ≥ 100,000 operations.
- Communication: Modbus RTU.
- Hysteresis: 1 to 100 (0.1 to 100) ℃/℉ for Thermocouple/RTD; 1 to 100 digits for Analog.
- Proportional Band (P): 1 to 999 (0.1 to 999.9) ℃/℉ for Thermocouple/RTD; 0.1 to 999.9 digits for Analog.
- Control Period (T): Ranges from 0.1 to 120.0 sec depending on output type.
- Manual Reset: Adjustable from 0 to 100 (0.0 to 100.0)%.
- Insulation: Double or reinforced insulation, with a dielectric strength of 1 kV between the measuring input and the power parts.
- Unit Weight: Approximately 178 g for the basic module, with packaging bringing it to about 251 g.
Input Specifications
- Thermocouple Input Types: Multiple types (K, J, E, T, B, R, S, N, C, G, L, U, Platinel II) with specific temperature ranges for both Celsius and Fahrenheit.
- RTD Input Types: Includes Cu50 Ω, Cu100 Ω, JPt100 Ω, DPt50 Ω, DPt100 Ω, Nickel120 Ω with specific ranges in Celsius and Fahrenheit.
- Analog Input Types: Includes 0 to 10 V, 0 to 5 V, 1 to 5 V, 0 to 100 mV, 0 to 20 mA, and 4 to 20 mA.
- Measurement Accuracy: Varies by sensor type and operating temperature, with typical room temperature accuracy of ±0.3% F.S. ±1 digit.
Documents
Can't find the information you need? Our datasheets have all the details. Access them here:
Additional Information
Channels: |
2 or 4 channels, expandable to 128 channels |
Sampling Rate: |
50 ms |
Measurement Accuracy: |
±0.3% |
Control Type: |
Heating, Cooling, Heating & Cooling (ON/OFF, P, PI, PD, PID) |
Communication: |
Modbus RTU, Modbus TCP |
Option Modules: |
Analog Input/Output, Digital Input/Alarm Output, CT Input |
Expansion Capability: |
Up to 32 units without additional wiring |
Communication Modules: |
Supports up to 16 communication modules per master device |
Supported Communication Protocols: |
RS422/RS485, Ethernet |
PC Connectivity: |
USB, RS422/RS485, Ethernet |
Accessories Sold Separately: |
Communication converters (SCM-series), Current transformers (CT), and CT connector cables (CICT4-□) |