Description

Application

The Prosonic Flow W 400 is an ideal ultrasonic clamp-on flowmeter for safe, cost-efficient, and maintenance-free measurement of both conductive and non-conductive liquids. It provides noninvasive, bidirectional flow measurement regardless of pressure, density, and conductivity, without any interruption to the process. FlowDC technology ensures exceptional installation flexibility, maintaining the specified accuracy with an inlet run as short as 2 x DN, even when flow profiles are disturbed. The special coupling pads make the ultrasonic clamp-on system entirely maintenance-free throughout its lifespan. Heartbeat Technology continuously provides process transparency through diagnostic, verification, and monitoring features, allowing detection of build-up before it impacts operation.


Benefits

  • Flexible Mounting: FlowDC minimizes required inlet runs, providing greater installation flexibility.
  • Reliable Measurement Performance: Proven sensors combined with a maintenance-free mounting system ensure long-term stable signals.
  • Low Capital Investment: Cost-effectiveness increases as the pipe diameter grows, accommodating pipes up to DN 4000 (160").
  • User-Friendly Operation: The integrated web server allows complete remote access, and the device’s display provides convenient on-site interaction.
  • Transparent Process Insights: Heartbeat Technology, with its built-in diagnostics, verification, and monitoring functions, ensures continuous compliance and process safety.

SPECIFICATIONS

Liquids Specifications

 

Measuring principle

 

 

 

Ultrasonic flow

 

 

Product headline

 

 

Clamp-on meter with Heartbeat Technology and web server for the water and wastewater industry.

Short inlet run thanks to FlowDC.

Bidirectional measurement for water and wastewater as well as process water and hydropower plants.

 

 

Sensor features

 

 

Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available.

Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature up to +130 °C (+266 °F).

 

 

Transmitter features

 

 

Safe operation – no need to open the device due to display with touch control, background lighting. Full remote access – web server. Integrated diagnostics, verification and monitoring – Heartbeat Technology.

Transmitter housing made of durable polycarbonate or aluminium. Remote version for wall mounting. Integrated data logger: measured values monitoring.

 

 

Nominal diameter range

 

 

DN15 to 4000 (1/2 to 160")

 

 

Sensor materials

 

 

Clamp on system:

Sensor holder 1.4301 (304), 1.4404 (316L)

Sensor housing 1.4301 (304), 1.4404 (316L)

Strapping bands 1.4301 (304), 1.4404 (316L)

 

 

Measured variables

 

 

Volume flow, Flow velocity, Sound velocity

 

 

Max. measurement error

 

 

Volume flow:

±3% o.r. for DN15

±2% o.r. for DN25 to 200

±2% o.r. above DN200

 

 

Measuring range

 

 

0 to 15 m/s (0 to 50 ft/s)

 

 

Max. process pressure

 

 

N/A

 

 

Medium temperature range

 

 

–40 to +130 °C (–40 to +266 °F)

 

 

Ambient temperature range

 

 

Sensor DN 15 to 65: -40 to 130°C

Sensor DN 50 to 4000: -40 to 130°C

 

Sensor housing material

 

N/A

 

Transmitter housing material

 

 

Wall-mounted housing

Polycarbonat; AlSi10Mg, coated

 

 

Degree of protection

 

 

Transmitter: IP66/67, Type 4X enclosure

Sensor: IP66/67, Type 4X enclosure, IP68, Type 6P enclosure (optional)

 

 

Display/Operation

 

 

4‐line backlit display with touch control (operation from outside)

Configuration via local display, web browser and operating tools possible

 

Outputs

 

3 ouputs:

4‐20 mA/4‐20 mA HART (active)

Pulse/frequency/switch output (passive)

Pulse/frequency/switch output (passive)

Modbus RS485

 

Inputs

 

Status input

 

Digital communication

 

 

HART

 

 

Power supply

 

 

AC 100 to 240 V / AC/DC 24 V

 

Approvals

 

cCSAus

 

Other approvals and certificates

 

Other approvals and certificates

 

Product safety

 

 

CE, C-tick marking, EAC-marking

 

 

Metrological approvals and certificates

 

 

other frequencies DN 100

Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

 

 

Marine approvals and certificates

 

 

Marine approvals and certificates

 

 

Documents

Can't find the information you need? Our datasheets have all the details. Access them here: