Endress+Hauser
Ultrasonic Transit Time Flowmeter Proline Prosonic Flow B 200
- SKU:
- Proline Prosonic Flow B 200 series
- Weight:
- 0.00 Grams
Description
Application
The Prosonic Flow B 200 is specially designed for accurate and reliable measurement of wet biogas and digester gas, even under varying process conditions. With its unique integrated real-time methane fraction analysis, it provides continuous monitoring of gas flow and gas quality. This enables efficient process control and energy balancing, while Heartbeat Technology ensures compliance and process safety at all times.
The measurement principle is unaffected by gas composition.
This inline flowmeter is optimized for wet biogas and digester gas applications in environments with fluctuating process conditions.
Device Properties:
- Multivariable device: measures flow, temperature, and methane content
- Medium temperature range: 0 to 80 °C (32 to 176 °F)
- Process pressure range: 0.7 to 11 bar absolute (10.2 to 159 psi absolute)
- Loop-powered technology
- Robust dual-compartment housing
- Plant safety ensured with worldwide approvals
Benefits
- Integrated real-time methane fraction measurement
- Specialized sensor design optimized for low-pressure gas
- Full bore design to eliminate additional pressure loss
- Enhanced process transparency through diagnostic capabilities
- Easy device wiring with a separate connection compartment
- Safe operation with touch control display and background lighting, eliminating the need to open the device
- Integrated verification with Heartbeat Technology
SPECIFICATIONS
Gas Specifications
Measuring principle
|
Ultrasonic flow
|
Product headline
|
The device for accurate, reliable biogas measurement with loop-powered technology. Inline flowmeter designed for measurement of wet biogas and digester gas under fluctuating process conditions.
|
Sensor features
|
Optimized for low pressure gas – specialized sensor design. No additional pressure loss – full-bore design. Process transparency – diagnostic capability. Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F). Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a).
|
Transmitter features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals.
|
Nominal diameter range
|
Single‐path version: DN 50 (2"), DN 80 (3") Two‐path version: DN 100 to 200 (4 to 8")
|
Wetted materials
|
Sensor: 1.4404/1.4435 (316L) Transducer: HNBR Temperature sensor (option): AFM 34
|
Measured variables
|
Volume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature |
Max. measurement error
|
Volume flow (standard): ‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s) ‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s) Volume flow (option): ‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s) ‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)
|
Measuring range
|
Standard: 1 to 30 m/s (3.28 to 98.4 ft/s) Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)
|
Max. process pressure
|
11 bar a (159 psi a) |
Medium temperature range
|
0 to +80 °C (+32 to +176 °F)
|
Ambient temperature range
|
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
|
Transmitter housing material
|
AlSi10Mg, coated; 1.4404 (316L)
|
Degree of protection
|
IP66/67, type 4X enclosure
|
Display/Operation
|
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
|
Outputs |
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
Inputs |
Current input 4‐20 mA (passive) Digital communication HART
|
Power supply
|
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch Output)
|
Hazardous area approvals
|
ATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN |
Metrological approvals and certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
|
Pressure approvals and certificates
|
PED
|
Material certificates
|
3.1 material (wetted parts)
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Proline Prosonic Flow B 200 Series datasheet.