Endress+Hauser
Vibronic Point level detection Liquiphant FTL33
- SKU:
- Vibronic Point level detection Liquiphant FTL33 series
- Weight:
- 0.00 Grams
Description
Application
The Liquiphant FTL33 is a compact point level switch for liquids, specifically engineered for the food and beverage industry, meeting stringent hygienic requirements. It provides reliable protection against overfilling and pump dry-run conditions. The built-in IO-Link interface facilitates seamless parameter configuration.
Compact Design:
- One of the smallest vibronic sensors on the market.
Safety Features:
- Continuous self-monitoring.
- Reliable switching, regardless of media properties.
Ease of Use:
- No calibration needed.
- Plug & play functionality.
- IO-Link compatibility for easy integration.
The Liquiphant FTL33 is a compact, hygienic point level switch with a robust stainless steel housing, ideal for the food industry.
Process Connections: Available in threaded options, hygienic connections, and an M24 process adapter.
Operating Conditions:
- Temperature Range: -40 to +150°C (-40 to +302°F)
- Pressure Range: -1 to +40bar (-14.5 to +580psi)
- Surface Roughness: 0.76µm or 1.5µm
Certified for overfill protection, leakage detection (WHG), and hygienic standards, complete with a final inspection report.
Benefits
The Liquiphant FTL33 is specifically designed for hygienic applications, particularly in the food industry. It features a variety of hygienic process connections and approvals. Its IO-Link capability simplifies device configuration, reducing both costs and system complexity.
The sensor supports CIP and SIP cleaning processes and boasts IP69k protection. Designed to meet the highest standards of quality and environmental sustainability, the Liquiphant offers safe switching even during power failures.
With its ability to provide accurate switching points regardless of changing media properties, the FTL33 is a true plug & play solution that requires no calibration. It works seamlessly in environments with varying conductivity, turbulence, or air bubbles and does not require specialized tools or software for setup.
Its rugged stainless steel (316L) construction ensures durability, while the absence of moving mechanical parts makes the device maintenance-free.
SPECIFICATIONS
Pressure Specifications
Measuring principle | Vibration Liquids |
Characteristic / Application |
Point level switch for liquids in the food sector |
Supply / Communication |
20 ... 253V AC/DC, 2-wire 10 ... 30V DC-PNP, 3-wire |
Ambient temperature |
-40 °C ... 70 °C (-40 °F ... 158 °F) |
Process temperature |
-40 °C ... 150 °C (-40 °F ... 302 °F) |
Process pressure / max. overpressure limit |
Vacuum ... 40 bar (Vacuum ... 580 psi) |
Min. density of medium |
>0,7g/cm³ (>0,5g/cm³ optional) |
Main wetted parts | 316L |
Process connection Threads: |
G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1 |
Process connection hygienic |
Flush mount by use of weld in adapter DIN11851 Tri-Clamp |
Communication |
AC/DC, DC-PNP, IO-Link |
Certificates / Approvals | CSA C/US, EAC |
Safety approvals |
Overfill protection WHG Leakage |
Design approvals | EN 10204-3.1 |
Hygienic approvals | 3A, EHEDG |
Options |
Switching delay Cleaned from oil+grease, Surface finish measurement |
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Vibronic Point level detection Liquiphant FTL33 Series datasheet.