The Liquiphant FTL50H is a point level switch designed for use in hazardous environments and is certified to meet international standards. It is particularly suited for the food and life sciences industries due to its hygienic certifications, including 3-A, EHEDG, and ASME BPE. The FTL50H provides reliable measurement even in challenging conditions, unaffected by changes in media properties, flow, turbulence, gas bubbles, foam, vibrations, or buildup.
This point level switch is compatible with all types of liquids and features a fully welded housing design.
Process Connections: Available with threaded, flanged, and a range of hygienic process connections such as Tri-Clamp, dairy coupling, aseptic, DRD, SMS, and Varivent.
Operating Range:
- Temperature: -50 to +150°C (-58 to +302°F)
- Pressure: -1 to +64 bar (-14.5 to +928 psi)
Sensor Material: 316L stainless steel
Additionally, the FTL50H is certified for international explosion protection, overfill protection (WHG), SIL, hygienic standards, and marine approvals.
Benefits
- Certified to international hygienic standards (3-A, EHEDG, ASME BPE) and made with FDA-compliant materials.
- Features an electro-polished and passivated surface finish for enhanced cleanliness.
- Equipped with international explosion protection certifications and overfill protection (WHG).
- The absence of mechanical moving parts ensures no maintenance, minimal wear, and an extended operational life.
- Integrated fork monitoring system to detect potential damage and guarantee functionality.
- Compatible with safety systems requiring SIL2/SIL3 functional safety in accordance with IEC 61508/IEC 61511-1.
- Easy startup with no need for calibration.
- A wide selection of standardized hygienic process connections, designed for applications that prioritize hygiene.
SPECIFICATIONS
Pressure Specifications
Measuring principle | Vibration Liquids |
Characteristic / Application |
Premium device for point level detection in hygienic/aseptic applications. Focus Food & Beverage and Life Sciences. Compact sensor version, Modular & completely welded housing concept, Wide range of certificates. |
Specialities |
Plug and play functionalities, Surface finish: mechanical or electro-polished, Density/Concentration measurement, SIL 2/3 according to IEC 61508 |
Supply / Communication |
PROFIBUS PA, 19 ..253V AC, 10...55V DC-PNP, 19...253V AC or 19...55V DC with relay DPDT, 8/16mA, NAMUR, PFM |
Ambient temperature |
-50 °C...+70 °C (-58 °F...+158 °F) |
Process temperature |
-50 °C...+150 °C (-58 °F...+302 °F) |
Process pressure / max. overpressure limit |
Vacuum...64 bar (Vacuum...928 psi) |
Min. density of medium |
0.5g/cm³ (0.4g/cm³ optional) |
Main wetted parts | 316L |
Process connection |
Threads (for weld-in adapter): G3/4A, G1A. Flange: DN25...DN100 ASME 1"...4", JIS 25A...100A |
Process connection hygienic |
Tri-Clamp, DIN 11851, DIN11864-1 Ingold, Flush mount, DRD, SMS1145, Varivent (Varinline) |
Sensor length | Compact sensor |
Communication | PROFIBUS PA |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Safety approvals |
Overfill protection WHG, SIL 2/ SIL 3 |
Design approvals |
Inspection certificate 3.1, EN10204, CoC ASME BPE, Conformity to cGMP, EU Food Contact Material (EC) 1935/2004, US Food Contact Material FDA CFR 21, CN Food Contact Material GB 4806, Declaration of Conformity ASME B31.3, AD2000, CRN approval |
Hygienic approvals |
3-A, EHEDG, CoC-ASME BPE |
Marine approval | GL/ ABS/ DNV |
Options | Customized settings (Density) |
Components |
FTL325P/FTL375P Interface PFM FTL325N/FTL375N Interface NAMUR |
Successor |
FTL63 |
Density Specifications
Measuring principle | Vibration Density |
Characteristic / Application |
Premium device for density measurement in hygienic/aseptic applications. Focus Food & Beverage and Life Sciences. Compact sensor version. Modular housing or completely welded compact housing. Wide range of certificates. |
Supply / Communication | via density controller FML621 |
Ambient temperature | -40 °C...70 °C (-40...158 °F) |
Process temperature | 0...80 °C (32…176 °F) |
Process pressure | 0...25 bar (0…362 psi) |
Wetted parts |
316L |
Hygienic |
3A EHEDG |
Sensor length | Compact sensor |
Output |
Pulse |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Specialities |
Density/Concentration measurement in combination with density controller FML621, Surface finish: mechanical polished (up to 0.3 µm) |
Components | Density Computer FML621 |