The Liquiphant FTL51C is a robust point level switch with an extension tube and a highly corrosion-resistant coating, designed for hazardous areas and certified to meet international standards. It is suitable for use across various industries. The FTL51C supports functional safety levels SIL2/SIL3, providing enhanced safety and reliability through its second line of defense. The device ensures accurate measurements unaffected by changing media properties, flow, turbulence, gas bubbles, foam, vibrations, or buildup.
It is an ideal point level switch for all types of liquids, featuring a corrosion-resistant coating for added durability.
- Process connections: Available with flanges and hygienic process connections (FDA compliant with PFA).
- Operating temperature range: -50 to +150°C (-58 to +302°F).
- Pressure range: -1 to +40 bar (-14.5 to +580 psi).
- Sensor materials: ECTFE, PFA (Edlon, Rubyred, conductive), Enamel.
- Comes with international explosion protection certificates, overfill protection (WHG), SIL, hygienic certificates, and marine approvals.
Benefits
- Ideal for safety systems requiring functional safety up to SIL2/SIL3, compliant with IEC 61508/IEC 61511-1.
- Offers a variety of plastic (PFA) and enamel coatings for handling aggressive media.
- Equipped with international explosion protection and overfill protection certificates (WHG).
- Simple setup with no need for calibration.
- With no mechanical moving parts, the device requires minimal maintenance, offering long-term operational reliability.
- Continuous fork monitoring ensures guaranteed functionality.
- The second line of defense provides additional environmental protection.
- A wide range of standardized process connections to meet various application needs.
SPECIFICATIONS
Pressure Specifications
Measuring principle |
Vibration Liquids |
Characteristic / Application |
High protection against aggressive media by using antistatic coating Modular housing concept wide range of process connections Analogue and bus interfaces Extensive certificate range (e.g.Ex,WHG) pipe extension up to 3m (6m option) |
Specialities |
Foamdetection Detekt a densitychange second line of defense |
Supply / Communication |
PROFIBUS PA 19...253V AC, 2-wire 10...55V DC-PNP, 3-wire DPDT, 19...253V AC, 10...55V DC 8/16mA, 11...36V DC NAMUR PFM, 2-wire NAMUR with testbutton |
Ambient temperature |
-50 °C...+70 °C (-58 °C...+158 °F) |
Process temperature |
-50 °C...+150 °C (-58 °F...+302 °F) up to 230 °C / 450°F on request |
Process pressure / max. overpressure limit |
Vacuum...40 bar (Vacuum...580 psi) |
Min. density of medium | 0.5g/cm³ (0.4g/cm³ optional) |
Main wetted parts |
ECTFE PFA (Edlon) PFA (Rubyred) PFA (conductive) Enamel |
Process connection |
Flange: DN25...DN100, ASME 1"...3", JIS RF10 K 50 |
Process connection hygienic | FDA conform with PFA (Edlon) |
Sensor length |
ECTFE, PFA 130mm, 148mm...3000mm (ECTFE, PFA 5.12", 5.83"...118") Enamel 130mm, 148mm...1200mm (Enmal 5.12", 5.83"...47.24") |
Communication |
PROFIBUS PA 19...253V AC 10...55V DC-PNP 19...253V AC bzw 10...55V DC 8/16mA, 11...36V DC NAMUR PFM |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Safety approvals |
SIL2/ SIL3 |
Design approvals |
EN 10204-3.1 |
Marine approval | GL/ ABS/ DNV |
Options | Heavy duty stainless steel housing mainly for the oil and gas industry |
Components |
FTL325P/FTL375P Interface PFM FTL325N/FTL375N Interface NAMUR |
Density Specifications
Measuring principle | Vibration Density |
Characteristic / Application |
Liquiphant M Density with Density Computer FML621 Temperature and pressure measurement High protection against aggressive media by using antistatic coating Modular housing concept Wide range of process connections Pipe extension up to 3 m (6 m option) |
Supply / Communication | Transmitter power supply (MUS) |
Ambient temperature |
-50...80°C -50...60°C for hazardous applications |
Process temperature |
0...80 °C (validity of accuracy data) -50...0°C / 80...150 °C (with reduced technical data) |
Process pressure |
0...25 bar >25...40 bar (with reduced technical data) |
Wetted parts | ECTFE, PFA and Enamel |
Sensor length |
115...3000 mm (depends by the covering) |
Output | Pulse |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Specialities | Commissioning with ReadWin2000 |
Components | Density Computer FML621 |
Measuring range |
Density range: 0.3 to 2 g/cm³ |
Other approvals and certificates | SIL2/ SIL3 |
Documents