null
Endress+Hauser

Vibronic Point Level Switch Liquiphant FTL81

(No reviews yet) Write a Review
SKU:
Liquiphant FTL81 series
Weight:
0.00 Grams
Call us: +971 4 259 5133

Description

Application

The Liquiphant FTL81 is a point level switch designed for use in hazardous environments and is certified with all major international approvals. It provides FailSafe overfill protection, supporting functional safety applications up to SIL3 with a single device. It delivers reliable measurements, unaffected by factors such as changing media properties, flow variations, turbulence, gas bubbles, foam, vibration, or build-up.

It is ideal for liquid level detection in SIL3 safety systems.

Key specifications:

  • Process connections: Available in threaded and flanged versions
  • Operating temperature range: -60°C to +280°C (-76°F to +540°F)
  • Pressure range: -1 to +100 bar (-14.5 to +1,450 psi)
  • Sensor length: Extension pipes available up to 3 meters (9.8 feet)
  • Sensor material: 316L stainless steel, Alloy C

It is compliant with international explosion protection standards, WHG overfill protection, SIL, and marine certifications.

 

 


 

Benefits

The Liquiphant FTL81 is designed for safety-critical systems requiring up to SIL3 certification, in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1, and DIN EN ISO 13849 standards.

  • Proof testing intervals extend up to 12 years, with easy testing of slave devices via a button press.
  • The device features continuous self-monitoring and internal redundancy to ensure reliability.
  • Easy integration is enabled through its 4-20mA interface (per NAMUR NE 06/NE 43), either via the Nivotester FailSafe FTL825 switching unit, which offers a two-channel safety contact output and a locking function, or directly into a safety PLC.
  • The device requires no adjustments for setup, allowing for a fast and cost-effective startup process.
  • Its design includes no moving mechanical parts, resulting in no maintenance requirements, no wear, and a long service life.
  • It continuously monitors for issues such as fork damage, corrosion, build-up, or mechanical blockages.

 

SPECIFICATIONS

Point Level / Liquids Specifications

 

Measuring principle

 

Vibration Liquids

 

Characteristic / Application

 

Reliable point level switch with extension pipe for MIN and MAX safety applications up to SIL3.

Dual Sealing / Second line of defense

Modular housing concept

 

Specialities

 

Outstanding features:

- permanent LIVE signal

monitors function safety

- failsafe design and

- high availability of the measuring values

 

Supply / Communication

 

2-wire 4...20 mA

 

Ambient temperature

 

-60°C...+70°C

(-76°F...+160°F)

 

Process temperature

 

-60°C...+280°C

(-76°F...+540°F)

 

Process pressure / max. overpressure limit

 

Vacuum...100 bar

(1450 psi)

 

Min. density of medium

 

Density from 0.4 g/cm3

(0.4 SGU)

 

Main wetted parts

 

316L

Alloy C

 

Process connection

 

Flange:

DN25...DN100,

ASME 1"...4",

JIS 10K...20K

Thread:

G3/4, G1, R3/4,

R1, MNPT3/4, MNPT1

 

Sensor length

 

Extension pipe up to 3 m (9.8 ft)

 

Communication

 

2-wire 4...20 mA

 

Certificates / Approvals

 

ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC

 

Safety approvals

 

Overfill protection WHG

Leakage Detection

SIL3

 

Design approvals

 

EN 10204-3.1

NACE MR0175, MR0103

ASME B31.3

AD2000

 

Marine approval

 

GL/ ABS/ LR/ BV/ DNV

 

Options

PWIS free

Pressure tight feed through

Weather protection

 

Components

 

Nivotester FTL825, Transmitter

 

 

Documents

You may want to read this product's catalog. If so, please click to view the Endress+Hauser Liquiphant FTL81 Series datasheet.