Endress+Hauser
Vibronic Point Level Switch Liquiphant FTL81
- SKU:
- Liquiphant FTL81 series
- Weight:
- 0.00 Grams
Description
Application
The Liquiphant FTL81 is a point level switch designed for use in hazardous environments and is certified with all major international approvals. It provides FailSafe overfill protection, supporting functional safety applications up to SIL3 with a single device. It delivers reliable measurements, unaffected by factors such as changing media properties, flow variations, turbulence, gas bubbles, foam, vibration, or build-up.
It is ideal for liquid level detection in SIL3 safety systems.
Key specifications:
- Process connections: Available in threaded and flanged versions
- Operating temperature range: -60°C to +280°C (-76°F to +540°F)
- Pressure range: -1 to +100 bar (-14.5 to +1,450 psi)
- Sensor length: Extension pipes available up to 3 meters (9.8 feet)
- Sensor material: 316L stainless steel, Alloy C
It is compliant with international explosion protection standards, WHG overfill protection, SIL, and marine certifications.
Benefits
The Liquiphant FTL81 is designed for safety-critical systems requiring up to SIL3 certification, in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1, and DIN EN ISO 13849 standards.
- Proof testing intervals extend up to 12 years, with easy testing of slave devices via a button press.
- The device features continuous self-monitoring and internal redundancy to ensure reliability.
- Easy integration is enabled through its 4-20mA interface (per NAMUR NE 06/NE 43), either via the Nivotester FailSafe FTL825 switching unit, which offers a two-channel safety contact output and a locking function, or directly into a safety PLC.
- The device requires no adjustments for setup, allowing for a fast and cost-effective startup process.
- Its design includes no moving mechanical parts, resulting in no maintenance requirements, no wear, and a long service life.
- It continuously monitors for issues such as fork damage, corrosion, build-up, or mechanical blockages.
SPECIFICATIONS
Point Level / Liquids Specifications
Measuring principle
|
Vibration Liquids
|
Characteristic / Application
|
Reliable point level switch with extension pipe for MIN and MAX safety applications up to SIL3. Dual Sealing / Second line of defense Modular housing concept
|
Specialities
|
Outstanding features: - permanent LIVE signal monitors function safety - failsafe design and - high availability of the measuring values
|
Supply / Communication
|
2-wire 4...20 mA
|
Ambient temperature
|
-60°C...+70°C (-76°F...+160°F)
|
Process temperature
|
-60°C...+280°C (-76°F...+540°F)
|
Process pressure / max. overpressure limit
|
Vacuum...100 bar (1450 psi)
|
Min. density of medium
|
Density from 0.4 g/cm3 (0.4 SGU)
|
Main wetted parts
|
316L Alloy C
|
Process connection
|
Flange: DN25...DN100, ASME 1"...4", JIS 10K...20K Thread: G3/4, G1, R3/4, R1, MNPT3/4, MNPT1
|
Sensor length
|
Extension pipe up to 3 m (9.8 ft)
|
Communication
|
2-wire 4...20 mA
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC
|
Safety approvals
|
Overfill protection WHG Leakage Detection SIL3
|
Design approvals
|
EN 10204-3.1 NACE MR0175, MR0103 ASME B31.3 AD2000
|
Marine approval
|
GL/ ABS/ LR/ BV/ DNV
|
Options |
PWIS free Pressure tight feed through Weather protection
|
Components
|
Nivotester FTL825, Transmitter
|
Documents
You may want to read this product's catalog. If so, please click to view the Endress+Hauser Liquiphant FTL81 Series datasheet.